Applies to: First Generation Plunge replacing a DC80 water pump with a CJ07 water pump.
Technician Note: Use accompanying step-by-step photos and video clips for visual reference.
Tools Required
8mm flex head hex nut driver
Drill with an 8mm nut driver
Flathead screwdriver/drywall saw
Pipe cutters
Clear PVC Cement
PVC primer / acetone
Utility knife or snips (for cutting zip ties)
Zip ties
Hose (if necessary)
Inline/immersion pump (if necessary)
Towel
First Generation Plunge - DC80 to RJ07 Water Pump Replacement
Power Down The Plunge
| |
Drain The Plunge
If the water needs to be drained to a different location use a hose and inline pump to move the water to a different location. | |
Disconnect Chiller Connections from Chiller
| |
Set Plunge on Its Side🚨There will still be water in the underneath plumbing so tipping the Plunge will result in water flowing out of the tub.🚨
|
First Generation Plunge DC80 to RJ07 Water Pump Replacement
Remove Water Pump Transformer
NOTE: If you have a heater on your Plunge you will need to remove the Inkbird Relay from the inside of the electrical box before removing the water pump transformer.
| |
Remove Water Pump From Tub
| |
Remove Insulation Foam to Expose Plumbing
| |
Remove Water Pump Elbow & Bulkhead
| |
Install Water Pump Elbow Bulkhead
| |
Assemble Elbow & AB Union
| |
Install Water Pump to Tub
| |
Attach Water Pump Transformer to Outside of Electrical Box🚨The water pump transformer must be mounted to the outside of the electrical box. DO NOT mount inside the electrical box.🚨
| |
Attach Male & Female Water Pump Connections
| |
Set Up and Fill Plunge with Water
| |
Test the Water Pump
|